# Texecom Premier Elite Programming Guide
Complete installation and programming reference for Texecom Premier Elite series intruder alarm panels.
## Overview
The Texecom Premier Elite series (Elite 12, Elite 24, Elite 48, Elite 64, Elite 168) offers flexible hardwired and wireless security solutions with comprehensive programming options via keypad or Wintex software.
## Prerequisites
– Engineer code (default: 4321)
– Wintex software (recommended)
– USB or Ethernet connection
– System design documentation
– Ricochet wireless devices (if applicable)
## Panel Configuration
### First Time Setup
1. Power up panel with default settings
2. Default engineer code: **4321**
3. Enter programming: **MENU 9** then engineer code
### Setting System Options
Navigate to **MENU 9-1** for system configuration:
| Option | Setting | Description |
|——–|———|————-|
| 1 | Panel Type | Select correct model |
| 2 | Mains Frequency | 50Hz (UK/EU) or 60Hz (US) |
| 3 | Date Format | DD/MM/YYYY |
| 4 | Time Format | 24-hour |
| 5 | Summer Time | Enable/Disable BST |
## Zone Programming
### Adding Hardwired Zones
1. Enter **MENU 9-3** (Zone Programming)
2. Select zone number (1-168 depending on panel)
3. Configure:
– Zone type
– Area assignment
– Zone text (20 characters max)
### Zone Type Reference
| Type | Description | Applications |
|——|————-|————–|
| Entry 1 | Entry/Exit route 1 | Main door |
| Entry 2 | Entry/Exit route 2 | Secondary door |
| Guard | Instant zone | Windows, sensors |
| 24hr | Always active | Panic, smoke |
| Keyswitch | Keyswitch input | Set/unset |
| Technical | Technical alarm | Freezer, boiler |
| Shunt | Bypass zone | Entry door |
### Ricochet Wireless Setup
#### Enrolling Wireless Devices
1. Enter **MENU 9-3**
2. Select zone for wireless device
3. Set zone type to "Wireless"
4. Press **LEARN** on keypad
5. Trigger device to enroll
#### Ricochet Device Types
| Device | Model | Battery Life |
|——–|——-|————–|
| PIR | Ricochet IR | 2-3 years |
| Door Contact | Ricochet MC | 3-5 years |
| Smoke Detector | Ricochet Smoke | 5 years |
| Panic Button | Ricochet PA | 2 years |
| External Siren | Ricochet Bell | Mains powered |
#### Signal Strength Testing
1. Enter **MENU 9-3** and select wireless zone
2. View signal strength indicator
3. Aim for 4-5 bars for reliable operation
4. Relocate expander if signal weak
## User Management
### Adding User Codes
1. Enter **MENU 9-6** (User Codes)
2. Select user number (1-999)
3. Enter 4-6 digit code
4. Assign attributes:
– Areas accessible
– Time restrictions
– User type
### User Types
| Type | Capabilities |
|——|————–|
| User | Set/Unset only |
| Manager | Set/Unset + User management |
| Engineer | All functions |
### Proximity Tags
1. Enter **MENU 9-6**
2. Select user
3. Present proximity tag to keypad
4. Tag automatically enrolled
## Area Configuration
### Setting Up Areas
Premier Elite supports up to 32 areas:
1. Enter **MENU 9-2** (Area Programming)
2. Select area number
3. Assign:
– Area name
– Entry time
– Exit time
– Siren time
### Entry/Exit Times
| Area Type | Entry Time | Exit Time |
|———–|————|———–|
| Main Entrance | 30-45 seconds | 30-45 seconds |
| Perimeter | 0 seconds | Instant |
| Internal | 30 seconds | Follow entry |
## Output Programming
### Configuring Panel Outputs
1. Navigate to **MENU 9-4**
2. Select output number
3. Configure trigger conditions:
– Event type
– Areas
– Time conditions
### Common Output Events
| Event | Description | Typical Use |
|——-|————-|————-|
| Burglar | Any alarm | Siren output |
| Fire | Fire zone alarm | Fire relay |
| Set | System armed | LED indicator |
| Unset | System disarmed | Status LED |
| Part Set | Night mode | LED indicator |
| Tamper | Tamper alarm | Separate siren |
## Communication Options
### IP Communicator Setup
1. Enter **MENU 9-7** (Communications)
2. Select IP module
3. Configure:
– IP address (static or DHCP)
– Subnet mask
– Gateway
– ARC IP and port
### DualCom/Emizon Setup
1. Navigate to **MENU 9-7-2**
2. Enter ARC account number
3. Configure reporting format (SIA III, CID)
4. Set test call interval (recommended: 24 hours)
### Texecom Connect (SmartCom)
For smartphone app integration:
1. Install SmartCom module
2. Pair with Connect app
3. Configure push notifications
4. Set user permissions
## Wintex Software
### Connection Methods
| Method | Speed | Best For |
|——–|——-|———-|
| USB | Fast | Local programming |
| Ethernet | Fast | Remote access |
| Serial | Slow | Legacy connections |
### Uploading Configuration
1. Connect to panel
2. Select **Upload from Panel**
3. Save .wtnx file
4. Edit configuration
5. Download to panel
### Batch Programming
Wintex allows batch changes:
1. Edit offline configuration
2. Use **Copy Zone** for similar zones
3. Export/import settings between panels
## Fault Diagnosis
### Common Fault Codes
| Display | Meaning | Action |
|———|———|——–|
| MAINS | Mains failure | Check power supply |
| BATT | Battery low/fault | Test/replace battery |
| TAMP | Tamper active | Check all tampers |
| FUSE | Panel fuse blown | Replace fuse |
| BUS | Comms bus fault | Check keypad wiring |
| RF LOW | Wireless low signal | Move/reposition device |
| RF BAT | Wireless battery low | Replace device battery |
### Zone Faults
| Status | Cause | Solution |
|——–|——-|———-|
| Open | Circuit open | Check wiring/EOL |
| Closed | Normal | – |
| Tamper | Tamper open | Check lid/contact |
| RFI | Interference | Shield cable |
## Testing Procedures
### Full System Test
1. Notify ARC of testing
2. Test each zone individually
3. Test entry/exit times
4. Test all outputs
5. Test communication
6. Document results
### Walk Testing
1. Enter **MENU 7** (Walk Test)
2. Panel beeps for each zone
3. Trigger all detectors
4. Exit walk test
5. Review any missed zones
### Battery Test
1. Disconnect mains power
2. Panel runs on battery
3. Monitor for low battery warnings
4. Test siren operation
5. Reconnect mains
## Advanced Features
### Chronodiary (Time Control)
1. Enter **MENU 9-8**
2. Set time-based events:
– Auto set/unset
– Output timers
– User restrictions
### Event Log
1. Enter **MENU 6** to view log
2. 1000 events stored
3. Export via Wintex
4. Filter by date/event type
### Custom Outputs
Complex logic programming:
– AND conditions (multiple events)
– OR conditions (any of events)
– Time windows
– Area-specific triggers
## Best Practices
1. **Use Wintex** for complex programming
2. **Backup regularly** – save .wtnx files
3. **Document zone text** clearly
4. **Test wireless signals** before final installation
5. **Label all devices** to match programming
6. **Verify communication** with ARC
7. **Train end users** on basic operation
## Troubleshooting Guide
### Panel Won't Power Up
– Check fuse (F1)
– Verify mains connection
– Test transformer output
– Check battery polarity
### Keypad Not Responding
– Check wiring (A, B, 12V, 0V)
– Verify keypad address
– Test with different keypad
– Check for short circuits
### Wireless Not Working
– Check expander power
– Verify signal strength
– Replace batteries
– Re-enroll devices
### False Alarms
– Review zone sensitivity
– Check for environmental factors
– Verify detector mounting
– Check wiring integrity
## Related Resources
– [Texecom Fault Code Reference](/texecom-fault-codes/)
– [Wintex Software Download](/wintex-software/)
– [Ricochet Wireless Guide](/ricochet-wireless-guide/)
—
*Last updated: February 2026*
*For qualified security engineers only. Follow manufacturer instructions and BS EN 50131 standards.*