<h2>Overview</h2>
<p>The Honeywell Galaxy Flex is a versatile intrusion detection system widely deployed across commercial and industrial premises. This commissioning checklist ensures your installation meets BS EN 50131 standards and Honeywell's technical requirements for reliable operation.</p>
<h2>Pre-Installation Checks</h2>
<h3>Site Survey Verification</h3>
<ul>
<li>Confirm Grade of system (Grade 1, 2, 3, or 4) matches client requirements</li>
<li>Verify environmental class (I, II, III, or IV) for installed location</li>
<li>Document cable routes and containment specifications</li>
<li>Check mains supply stability and earth bonding requirements</li>
<li>Identify any RF interference sources affecting wireless components</li>
</ul>
<h3>Panel Inspection</h3>
<ul>
<li>Verify panel model matches specification (Flex 20/50/100)</li>
<li>Check firmware version is current (minimum V3.13 recommended)</li>
<li>Inspect all PCBs for physical damage or moisture ingress</li>
<li>Confirm battery capacity matches standby requirements (VdS-approved battery required)</li>
</ul>
<h2>Hardware Installation</h2>
<h3>Control Panel Mounting</h3>
<ul>
<li>Install in accordance with BS EN 50131-1 location requirements</li>
<li>Maintain minimum 300mm clearance from mains distribution</li>
<li>Ensure panel is not mounted directly on metal surfaces (use standoffs)</li>
<li>Verify tamper switches engage correctly when lid and front cover fitted</li>
</ul>
<h3>Wiring Verification</h3>
<ul>
<li>Loop resistance within specification (max 50Ω per loop)</li>
<li>All cables correctly terminated and strain-relieved</li>
<li>Separate containment for mains (230V) and extra-low voltage circuits</li>
<li>Earth continuity verified (< 1Ω between panel earth and main earthing terminal)</li>
</ul>
<h2>Programming & Configuration</h2>
<h3>System Defaults</h3>
<ul>
<li>Load factory defaults before custom programming</li>
<li>Set correct date, time, and DST parameters</li>
<li>Configure GRADE setting to match certification requirements</li>
<li>Enable appropriate handover procedures per EN 50131</li>
</ul>
<h3>Zone Programming</h3>
<ul>
<li>Each zone assigned appropriate type (Entry/Exit, Immediate, Final Exit, etc.)</li>
<li>Zone response times configured per BS EN 50131-1 Table 6</li>
<li>Double-knock enabled where specified (high-risk areas)</li>
<li>Walk testing completed for all detection devices</li>
</ul>
<h3>User Management</h3>
<ul>
<li>Master code changed from factory default</li>
<li>User codes programmed with appropriate authority levels</li>
<li>Duress codes configured and tested</li>
<li>Keyfobs/Tags enrolled and assigned to correct users</li>
</ul>
<h2>Communication Setup</h2>
<h3>IP Module Configuration (Galaxy ETH-001)</h3>
<ul>
<li>Static IP assigned within customer's network range</li>
<li>Subnet mask and gateway configured correctly</li>
<li>Monitoring station IP and port programmed</li>
<li>SIA or Contact ID protocol confirmed with ARC</li>
<li>Test transmissions verified (minimum 3 successful signals)</li>
</ul>
<h3>GSM/GPRS Backup (if fitted)</h3>
<ul>
<li>SIM card active and sufficient credit/data allowance</li>
<li>Signal strength adequate (minimum -85 dBm recommended)</li>
<li>Test calls via GSM path verified</li>
<li>Failover from IP to GSM confirmed under test conditions</li>
</ul>
<h2>Testing Procedures</h2>
<h3>Functional Testing</h3>
<ul>
<li>Full set/unset sequence from all codepads</li>
<li>Entry/Exit timing verified at all entry points</li>
<li>Alarm activation from every detection device</li>
<li>Tamper protection on all enclosures tested</li>
<li>Mains fail and battery discharge tests completed</li>
</ul>
<h3>Remote Signalling</h3>
<ul>
<li>All alarm types transmitted and acknowledged by ARC</li>
<li>Line fault reporting verified (if monitored line fitted)</li>
<li>Regular test signal (keep-alive) confirmed</li>
<li>Remote unset authority tested (if applicable)</li>
</ul>
<h2>Documentation & Handover</h2>
<h3>Certificates & Records</h3>
<ul>
<li>Installation certificate completed per NSI/NACOSS requirements</li>
<li>Loop resistance readings recorded</li>
<li>Battery discharge test results documented</li>
<li>Zone list and device locations marked on site drawings</li>
<li>User codes sealed in envelope and secured</li>
</ul>
<h3>User Training</h3>
<ul>
<li>Set/unset procedures demonstrated</li>
<li>Isolation of faulty zones explained</li>
<li>Emergency procedures covered</li>
<li>User manual provided (or download link supplied)</li>
<li>24-hour monitoring station telephone number provided</li>
</ul>
<h2>Fault Code Quick Reference</h2>
<table style="border-collapse: collapse; width: 100%;">
<thead>
<tr style="background-color: #f2f2f2;">
<th style="border: 1px solid #ddd; padding: 8px; text-align: left;">Code</th>
<th style="border: 1px solid #ddd; padding: 8px; text-align: left;">Description</th>
<th style="border: 1px solid #ddd; padding: 8px; text-align: left;">Action</th>
</tr>
</thead>
<tbody>
<tr>
<td style="border: 1px solid #ddd; padding: 8px;">E01</td>
<td style="border: 1px solid #ddd; padding: 8px;">Battery Low/Disconnected</td>
<td style="border: 1px solid #ddd; padding: 8px;">Check battery voltage and connections</td>
</tr>
<tr>
<td style="border: 1px solid #ddd; padding: 8px;">E02</td>
<td style="border: 1px solid #ddd; padding: 8px;">Mains Fail</td>
<td style="border: 1px solid #ddd; padding: 8px;">Verify 230V supply and panel fuse</td>
</tr>
<tr>
<td style="border: 1px solid #ddd; padding: 8px;">E03</td>
<td style="border: 1px solid #ddd; padding: 8px;">Zone Tamper</td>
<td style="border: 1px solid #ddd; padding: 8px;">Locate and secure device enclosure</td>
</tr>
<tr>
<td style="border: 1px solid #ddd; padding: 8px;">E04</td>
<td style="border: 1px solid #ddd; padding: 8px;">Panel Tamper</td>
<td style="border: 1px solid #ddd; padding: 8px;">Check lid and front cover switches</td>
</tr>
<tr>
<td style="border: 1px solid #ddd; padding: 8px;">E05</td>
<td style="border: 1px solid #ddd; padding: 8px;">Comms Fail</td>
<td style="border: 1px solid #ddd; padding: 8px;">Verify IP/GSM connectivity</td>
</tr>
<tr>
<td style="border: 1px solid #ddd; padding: 8px;">E06</td>
<td style="border: 1px solid #ddd; padding: 8px;">Fuse Fault</td>
<td style="border: 1px solid #ddd; padding: 8px;">Check auxiliary fuses F1, F2, F3</td>
</tr>
<tr>
<td style="border: 1px solid #ddd; padding: 8px;">E07</td>
<td style="border: 1px solid #ddd; padding: 8px;">Earth Fault</td>
<td style="border: 1px solid #ddd; padding: 8px;">Test earth continuity; check for cable damage</td>
</tr>
<tr>
<td style="border: 1px solid #ddd; padding: 8px;">E08</td>
<td style="border: 1px solid #ddd; padding: 8px;">Clock Lost</td>
<td style="border: 1px solid #ddd; padding: 8px;">Reset date/time; check battery backup</td>
</tr>
<tr>
<td style="border: 1px solid #ddd; padding: 8px;">E50</td>
<td style="border: 1px solid #ddd; padding: 8px;">Keypad Comms Fail</td>
<td style="border: 1px solid #ddd; padding: 8px;">Check keypad addressing and wiring</td>
</tr>
<tr>
<td style="border: 1px solid #ddd; padding: 8px;">E70</td>
<td style="border: 1px solid #ddd; padding: 8px;">RF Device Low Battery</td>
<td style="border: 1px solid #ddd; padding: 8px;">Replace device battery immediately</td>
</tr>
</tbody>
</table>
<h2>Maintenance Schedule</h2>
<p>Per BS EN 50131-1, the Galaxy Flex requires:</p>
<ul>
<li><strong>Weekly:</strong> User visual inspection of indicators</li>
<li><strong>Monthly:</strong> Remote signalling test (if monitored)</li>
<li><strong>Annually:</strong> Full maintenance inspection by competent person</li>
<li><strong>Battery:</strong> Replacement every 3-5 years (or per VdS test results)</li>
</ul>
<h2>Additional Resources</h2>
<ul>
<li><a href="https://buildings.honeywell.com/galaxy-flex">Honeywell Galaxy Flex Product Page</a></li>
<li>Galaxy Flex Programming Manual (MK7-MK8 Keypads)</li>
<li>BS EN 50131-1:2006+A3:2020 – Alarm Systems</li>
<li>NSI NCP 104 Issue 6 – Auditable Document Requirements</li>
</ul>
<p><em>Document Version: 1.0 | Last Updated: February 2026 | Compliant with BS EN 50131-1:2006+A3:2020</em></p>